When somebody pulls the fire alarm they re usually talking about fire alarm pull stations.
Fire alarm pull station height canada.
The cover is connected to the frame by a cable.
In a forward reach the wheelchair user approaches the object head on.
Fire alarm engineering best practices 3 code compliance 2012 ontario building code and or 2010 national building code of canada standards referenced can ulc s524 standard for the installation of fire alarm systems latest issue is 2014 can ulc s537 standard for the verification of fire alarm systems.
1 1 2 the provisions of this chapter apply throughout the code unless otherwise.
The ontario building code manual pull stations 3 2 4 18.
We have converted the 229 meter entry on the line next to it to reflect the corrected imperial measurement of 751.
When the cover is lifted it hangs off of the frame until the cover is snapped back onto the frame.
Manual fire alarm activation requires human intervention as distinct from automatic fire alarm activation such as that provided through the use of heat detectors and smoke.
Nicet fire alarm systems levels 1 2 study guide.
The ada provides two ways to make operable parts accessible to wheelchair users.
It consists of a tamperproof clear lexan shield and frame that fits easily over a manual pull station.
Unique patented device helps prevent false fire alarms without restricting legitimate alarms.
2018 nicet fire alarm systems level 1 study guide.
2018 nicet fire alarm systems level 2 study guide.
1 1 1 nfpa 72 covers the application installation location performance inspection testing and maintenance of fire alarm systems supervising station alarm systems public emergency alarm reporting systems fire warning equipment and emergency communications systems ecs and their components.
Manual pull stations 1 except as permitted by sentences 2 and 3 if a fire alarm system is installed a manual pull station shall be installed a near the principal entrance to thebuilding and b near every required exit.
Section 17 14 5 states the operable part of a manual actuated alarm initiating device shall not be less than 42 1 07 m and not more than 48 1 22 m from the finished floor.
Ada fire extinguisher heights and fire alarm pull station placement must allow wheelchair users access and ease of operation.
Through a forward reach or a side reach.
The line item for the 030 ampere 16awg entry is shown as 150 feet in table 5 of the fa 1000 installation manual.
An introduction to fire alarm systems.
For more than 50 years some form of these typically red boxes have been found on the walls of most large buildings in the united states.
End of line resistors may be mounted in a properly identified common termination box or inside the fire alarm system s.
2 in a building that is sprinklered a manual pull station is not required at an exterior egress.
A working fire alarm pull station supports prompt evacuation and swift action from first responders.